Home
Pros
Forum
  • About
  • Register
  • Contact
InboxSent
MembersPros
WatchingStarredHistory
Brad75
120 Posts
Brad75
120 Posts
Senior Member

Follow
120PostsMost Active Topics

Brad75

Joined 30 May 2008
Senior Member
12 years12 yearsBrad75Brad75 posted:
Braemar ducted heater with Actron SRA161C addon cooling

No it cant you can only use the Braemar spectrolink but you can have upto 4 of them

12 years12 yearsBrad75Brad75 posted:
Plumbing inspector for the air con duct work?

How did you go did you get onto a plumbing inspector bout your system ?

12 years12 yearsBrad75Brad75 posted:
Braemar gas heater issue

It will be your themister cable had plenty already this year mice chew through them

12 years12 yearsBrad75Brad75 posted:
best time of the year to install air conditioner?

Right nows a good time if your in Melb as the summer was crap and alot of companys have alot of stock they need to get rid of prices are…

12 years12 yearsBrad75Brad75 posted:
Bonaire vs Brivis

Do yourself a favor and check out Braemar

13 years13 yearsBrad75Brad75 posted:
Brivis Buffalo 85 Blowing Cold Air

Well said pattycake4 what people don't realise is playing around with gas appliances are a dangerous thing and what they don't seem to realise if something goes wrong with their…

13 years13 yearsBrad75Brad75 posted:
Zoning ducted heating/cooling

Sounds like this Air con installer just started his apprenticeship

13 years13 yearsBrad75Brad75 posted:
Brivis Buffalo 85 Blowing Cold Air

So i take it your a registered plumber then ?

13 years13 yearsBrad75Brad75 posted:
Evap ducts won't fit through trusses

Hear this story over & over again plans don't show where every timber is going to be and it's normally the problem of people wanting a low roof pitch but…

13 years13 yearsBrad75Brad75 posted:
Actron in Melbourne, install cost??

Thats very cheap i'm not gonna move to Newcastle to soon thats bout how much i would charge to supply equipment with no installation and add gst to that price

13 years13 yearsBrad75Brad75 posted:
Brivis Ducted Heater HE20I Problem

Thermister in the duct work maybe to close thermister temparture shouldn't go above 65 degrees your heaters going out on over temp how old is the unit ?

13 years13 yearsBrad75Brad75 posted:
Actron in Melbourne, install cost??

Thats a pretty good price you will find prices vary a fair bit from different states in Melbourne they normally work on $1,000 per kilo watt

13 years13 yearsBrad75Brad75 posted:
Brivis Ducted Heating Problem-need a good repairer

Try Steere heating & cooling in Pascoe Vale

13 years13 yearsBrad75Brad75 posted:
Return air vent query - Bonaire Gas Ducted Heating

Return air filters are a option on heaters so most companies will charge extra and keep in mind if you do want filter later on don't just fit 1 to…

13 years13 yearsBrad75Brad75 posted:
House is nearly done but can't see any refrigerant pipes

Sounds like they have forgotten to rough them in the only way now will be down on the outside walls then covered up with capping would have looked much better…

13 years13 yearsBrad75Brad75 posted:
Bonaire Problem! Urgent Help Required

Who's w w ?
Anyway that price he gave you is a bargin and would be a very good choice don't forget to make sure you get a plumbing compliance certficate…

13 years13 yearsBrad75Brad75 posted:
Bonaire Problem! Urgent Help Required

What .2 of a star more than a Braemar what you think you are going save maybe a few cents difference each quarter you may even save more if the…

13 years13 yearsBrad75Brad75 posted:
heating

I agree with B STAR go the TH430 and his right no need for XA fan unless you wanna add airconditioning to it

13 years13 yearsBrad75Brad75 posted:
Where should the recycled air vent go

Rod don't waste your money putting return air in ceiling with 3m ceilings is a complete no no 2.4m not so bad but forget it with high ceilings it just…

13 years13 yearsBrad75Brad75 posted:
Bonaire Problem! Urgent Help Required

Because they are best heater on the market these days
Bonaire - Builder's delight
Brivis - Was a great heater but not anymore
Omega - What is that
Lennox - Not a…

13 years13 yearsBrad75Brad75 posted:
Bonaire Problem! Urgent Help Required

Remove it and install a Braemar

13 years13 yearsBrad75Brad75 posted:
Actron in Melbourne, install cost??

I think he maybe meaning Harvey Norman in WA they used have a store in melbourne just for heating & cooling but it didn't last long in regards to price…

13 years13 yearsBrad75Brad75 posted:
Add on Air Conditioning to existing Ducts

The system is designed for a 13 degree drop in temparture so on a 38 degree day it should get your house down to 25 which is very comfortable anyway…

13 years13 yearsBrad75Brad75 posted:
Braemar Heating Problem

Gas supply turned off
Ignition led damaged or disconnected
Incorret gas supply pressure
Incorrect burner pressure
Incorrect spark gap OT3 open (located on burner cover)
EFS not dectecting flame signal-ignition occurs but gas turns off…

13 years13 yearsBrad75Brad75 posted:
Cost of ducted heating changeover

Yeah but Braemar have the most efficent heaters over all and you don't have to wait a month for them to come for warranty break downs or be on hold…

13 years13 yearsBrad75Brad75 posted:
Daikin: Supply shortage due to tsunami

ActronAirs the way to go it's more efficent than Daikin anyway

13 years13 yearsBrad75Brad75 posted:
Daikin: Supply shortage due to tsunami

Most Daikin units won't be available till January 2012 and no you can't use any other unit if you already have the fan coil unit installed in roof space already

13 years13 yearsBrad75Brad75 posted:
DIY Ducted Reverse Cycle Air Conditioning

You have to be a licensed plumber with mechanical or duct fixing license to be able to install ducting and it's not as easy as it looks on video i'm…

13 years13 yearsBrad75Brad75 posted:
Bit of a challenging problem...

Brivis still make a upflow unit but they are noisy and not very efficent
i would go wall hung split systems this is a very common problem people not thinking…

13 years13 yearsBrad75Brad75 posted:
Brivis Or Braemar?

The guy is telling you crap you should be going 3 zones with 3 spectrolinks so then you don't need a common zone
Most efficent why togo is by going…

About

Occupation

Plumber

More
Joined homeone
30 May 2008

Australia's largest home building and renovation
community with over 1.8 million posts

Home
Pros
Forum
Start a new topic
About
Advertise
Contact Homeone
Articles
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024

Australia's largest home building and
renovation community
Homeone
About

Terms
Privacy

Follow homeone on FacebookFollow homeone on Twitter
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024