Home
Pros
Forum
  • About
  • Register
  • Contact
InboxSent
MembersPros
WatchingStarredHistory
bzerk86
12 Posts
bzerk86
12 Posts
Junior Member

Follow
12PostsMost Active Topics

bzerk86

Joined 3 February 2010
Junior Member
Followers
7 years7 yearsbzerk86bzerk86 posted:
Daikin 20kW Premium Inverter

Keep in mind that Daikin units 20kw and above including large VRV systems are only rated to work with an outside temperature of 43c.
Anything above this they won't operate at…

  ⋅  1
8 years8 yearsbzerk86bzerk86 posted:
Daikin Ducted Inverter - Doesn't Slow Down In Heat Mode

Okay,
I have been fortunate enough to have a Daikin tech on site.
Turns out that this particular model of Three phase inverters will only modulate in cooling mode.
The technician called…

8 years8 yearsbzerk86bzerk86 posted:
Daikin Ducted Inverter - Doesn't Slow Down In Heat Mode

A quick update.
Have now had multiple technicians look at the unit and none have been able to diagnose the issue even though they have all witnessed it and say it's…

8 years8 yearsbzerk86bzerk86 posted:
Daikin Ducted Inverter - Doesn't Slow Down In Heat Mode

Yeah, I have changed the temp sensing point, fan continuous, low low and off with compressor and tried all the different combinations. The outside unit is either "on or…

8 years8 yearsbzerk86bzerk86 posted:
Daikin Ducted Inverter - Doesn't Slow Down In Heat Mode

It's set to heat, low fan, half of the zones are on.
Just to confirm this is a ducted reverse cycle unit.

8 years8 yearsbzerk86bzerk86 posted:
Daikin Ducted Inverter - Doesn't Slow Down In Heat Mode

I have recently moved into a new home that has the following Daikin ducted air conditioner set up:
Outdoor Unit: RZQ150HY4A (Super Inverter)
Indoor Unit: FDYQ160KAV1
Controller: BRC1E61
When in heating mode the system…

14 years14 yearsbzerk86bzerk86 posted:
Multi-head split system

I have heard that myself, but with all brand (but Actron) as they are no longer made in Japan. Using cheap thin copper and lower quality componenets in China, I…

14 years14 yearsbzerk86bzerk86 posted:
Multi-head split system

That is fantastic!
Can I ask what brand you went with?

14 years14 yearsbzerk86bzerk86 posted:
Multi-head split system

Depending on the brand and installer, I beleive the cost is comparable to a zoned ducted system, if anything it would have a slight premium as it is not a…

14 years14 yearsbzerk86bzerk86 posted:
Multi-head split system

4 at the most,
One in each bedroom and one in the main living area.
The KW works out to be the same as a normal ducted unit,
7-8KW for the main living…

14 years14 yearsbzerk86bzerk86 posted:
Multi-head split system

Anyone have a Multi-head split system? Any advice, experience, do's and don'ts?
For those who don't know, it's where you can have multiple indoor units connect to one outdoor unit.
I was…

14 years14 yearsbzerk86bzerk86 posted:
Electricity Bill NSW

Origin are the more expensive to use, get TRU if available, pay by the due date and get 10% off!

Most Active Topics

Joined homeone
3 February 2010

Australia's largest home building and renovation
community with over 1.8 million posts

Home
Pros
Forum
Start a new topic
About
Advertise
Contact Homeone
Articles
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024

Australia's largest home building and
renovation community
Homeone
About

Terms
Privacy

Follow homeone on FacebookFollow homeone on Twitter
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024