13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Small pine sleeper retaining wall - advice for novice

As long as your slepers area treated to at least H4 rating which they pretty much all are you should be fine to put them straight on or slightly in…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
urgent advice - bolted cap screw

I would be wanting a cast iron cover (as suggested by Davinci) in a heavy traffic area like a drive way. Are those PVC covers able to be driven…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
A question about the storm water pipes

I can understand why it doesn't look very nice then. Maybe you need to discuss it further with your plumber. It probably took him less time to do it…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
How to tell if the Tiler is good?

My Tiler told me the most important room in the house to get right is the toilet because thats where you spend the most time just sitting and looking around.…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Shower - Grate Drains, opinions?

I've installed a couple of them. I had 100mm or so to the wall at each end for each of the installations. They looked great a had no ongoing problems.…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Guttering Standards

We had a problem with undersized box guttering in our recently built home. Had intermitent drips from our ceiling for over 18 months. Builder has now re routed…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Does this need to be fixed, and if so, how?

I would check your steelwork connection details for this area against the engineers drawings as well. It doesn't look quite right from these limited photos. May be all…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Standard Water run-in - What is it in West Aust?

Yes I would read it that way. Anything over and above the 7.5m would be an additional cost to you.

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Standard Water run-in - What is it in West Aust?

I understand this to be from the meter to closest point of the house. I know most of the volume builders quote a fixed amount for a certain front…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
The bug bites again

I look forward to seeing pics of the staw bale method of building. I've heard about it before but never seen it done. Keep us informed.

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Fixing a bad brick job - Is render the only answer?

I have seen Nawkaw used on mortar discolouration as bad as yours and it looked great afterward. Have not seen it after applying to bricks though.

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
A question about the storm water pipes

I don't believe there are any codes which state they should be under ground. If its an eysore you should tell him its not as you discussed. If…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
90% of house perimeter brick wall overhang by more than 30mm

30mm definitely exceeds the allowable limit of brickwork overhanging the slab. When it is so widespread I would make sure the builder gets the engineer involved to either ok…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Does this need to be fixed, and if so, how?

Main problem I see is that they have cut the bottom plate (horizontal timber at the base) too short and so therefore the end stud (vertical timber closest to steel…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Plastic Mains Water Pipes

Just to answer your question re the wall thickness of mains pipe versus the domestic pipe. The required wall thickness is a function diameter. ie a larger pipe…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
hi, newbie after some advice any help would be great!!

Very difficult to do electrical work after the plaster is up. If your builder is charging too much for the extras (which is why I'm assuming you've asked the…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Clarendon Homes in Melbourne or GEELONG?

I know a few people who have built with them. Like all of the volume builders it can depend on the sub contractors you get on the day. …

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
2400 Ceilings

If you can afford the upgrade I would at least go half way to 2550. Much more spacious.
Also depends where you are building. Where we are we had trouble…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
Concrete Curing period ?????? How many days ? ???

The building code states, Loading of concrete slabs with stacked materials or building plant must not occur for a minimum of 7 days after pouring although construction of wall frames…

13 years13 yearsMalcolm AxfordMalcolm Axford posted:
HELP! am I over-reacting?

We had 5 different site supervisors and 4 different customer service people durring our build. We had endless discussions caused by lack of continuity and lost information along the…

Joined homeone
23 May 2011

Australia's largest home building and renovation
community with over 1.8 million posts

Home
Pros
Forum
Start a new topic
About
Advertise
Contact Homeone
Articles
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024

Australia's largest home building and
renovation community
Homeone
About

Terms
Privacy

Follow homeone on FacebookFollow homeone on Twitter
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024