proxemic

Joined 10 August 2013
Junior Member
11 years11 yearsproxemicproxemic posted:
Gas space heater room fan stopping

Ok so at least some consistency, room fan has stopped working.. permanently.
I think i am going to give up at this point i only paid a few hundred for the…

11 years11 yearsproxemicproxemic posted:
Gas space heater room fan stopping

Yeh in Melbourne.
The problem as usual is the fault is intermittent, which in my experience is costly to 'attempt' to diagnose.
I write this as the heater is running fine,…

11 years11 yearsproxemicproxemic posted:
Gas space heater room fan stopping

Well the pressure switch is doing its job starts and runs every time, which it didn't do before.
Now the room fan stops intermittently. But if i let it cool for…

11 years11 yearsproxemicproxemic posted:
Gas space heater room fan stopping

Hi all
As the above says. It's a Rinnai Inbuilt Gas Heater, model is REH-300. The room fan will randomly stop. Then safety kicks in and whole heater shuts down.
Heater…

11 years11 yearsproxemicproxemic posted:
Rinnai High Efficiency Inbuilt Gas Space Heater Problem

Well i installed a new pressure switch and started straight up, seeing as it hasn't worked for the last 3 days i think that solves it!
Thanks for your help guys.
During…

11 years11 yearsproxemicproxemic posted:
Rinnai High Efficiency Inbuilt Gas Space Heater Problem

No idea.
Can email you the circuit diagram if you like...

11 years11 yearsproxemicproxemic posted:
Rinnai High Efficiency Inbuilt Gas Space Heater Problem

So yesterday I gave the pressure switch a good wack with the butt end of my screwdriver, then it started! So i turned it off and it started again and…

11 years11 yearsproxemicproxemic posted:
Rinnai High Efficiency Inbuilt Gas Space Heater Problem

My understanding is that it wouldn't fire up and run at all if the thermocouple was done, is this incorrect?

11 years11 yearsproxemicproxemic posted:
Rinnai High Efficiency Inbuilt Gas Space Heater Problem

Hi all
So where do i start!!
I have a 2004 Rinnai High Efficiency 30 Inbuilt Gas Space Heater. Unit was working great and still does intermittently.
Worked fine for as long…

Joined homeone
10 August 2013

Australia's largest home building and renovation
community with over 1.8 million posts

Home
Pros
Forum
Start a new topic
About
Advertise
Contact Homeone
Articles
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024

Australia's largest home building and
renovation community
Homeone
About

Terms
Privacy

Follow homeone on FacebookFollow homeone on Twitter
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2024