1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

Thanks to everyone for your comments, it's helped pick up a few errors in my original calculations (now fixed hopefully) and made our decision much clearer.
We'll just upgrade the windows…

1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

Are you saying that an average 1kwh saving per day is too big a saving for the increase in insulation?
I guess there's some other factors to consider: these calculations…

1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

If you have a look at the U values and the area covered by the insulation it makes sense.
Increasing ceiling from R5-R6 decreases U value by approx 0.033 (1/5 -…

1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

I had another look at this tonight and my calculations were very wrong. I was using the calculator I linked incorrectly and using the total new R value for the…

1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

No, we actually have a void above the dining area which is also adjacent the stair well, so I don't expect the between floors to do anything for the hallway…

1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

Thanks!
Upstairs floors are carpeted. I guess the point of insulating between floors is to reduce the heat escaping from heating zones t reduce heating requirements when you only need to…

1 month1 monthrockedoutrockedout posted:
Comparison of insulation upgrades

I've been doing some comparisons of potential insulation upgrades that we're thinking of adding to our tender and thought I would share them as I wasn't able to find much…

1 month1 monthrockedoutrockedout posted:
Thomas Archer Hive 46 (customised) Build 2020-21

We're going through tender currently and have a similar set of upgrades. Some other things we have are Anticon 60 (R1.3) roof blanket and R1.5 HVAC ducts (think standard is…

1 month1 monthrockedoutrockedout posted:
Thomas Archer Bayside Build

I think I understand what you're saying that the +/- may be more to do with floor finish than building tolerance, but that aside there is still 5mm (potentially up…

1 month1 monthrockedoutrockedout posted:
Thomas Archer Bayside Build

We're also going through tender stage with TA at the moment and had requested our corner stacker to be recessed, however in the tender it has a note "Note: Bottom…

  ⋅  1
Joined homeone
17 October 2020

Australia's largest home building and renovation
community with over 1.7 million posts

Home
Pros
Forum
Start a new topic
About
Advertise
Contact Homeone
Articles
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2020

Australia's largest home building and
renovation community
Homeone
About

Terms
Privacy

Follow homeone on FacebookFollow homeone on Twitter
All comments made express the views and opinions of the author and not the Administrators, Support nor Homeone Australia & New Zealand
© Homeone Australia & New Zealand All Rights Reserved ‎2001 - 2020